Line Plot from Scientific Research

CC-BY
0
Views
0
Likes
Citation
The ON state conductance decreased by a factor of 4 after >2,000 actuation cycles and 6 months of magnet aging at room temperature; we attribute the reduction to a decrease in magnetic strength of the permanent magnets and wear on the TIM (see inset image), both of which decrease the interfacial thermal conductance. Error bars represent standard error of Gon.
#Line Plot#Error Bars#ON State Conductance#Actuation Cycles#Magnet Aging#Magnetic Strength#Thermal Conductance